Mostrar el registro sencillo del ítem

dc.contributor.authorNollas, Fernando Martín
dc.date.accessioned2021-06-08T15:44:41Z
dc.date.available2021-06-08T15:44:41Z
dc.date.issued2021-06
dc.identifier.citationNollas, F., 2021: Calibración de Piranómetros s/n 163812, 830285 y 120928. Nota Técnica SMN 2021-94.es
dc.identifier.urihttp://hdl.handle.net/20.500.12160/1574
dc.descriptionFil: Nollas, Fernando Martín. Servicio Meteorológico Nacional. Dirección Nacional de Ciencia e Innovación en Productos y Servicios. Dirección Central de Monitoreo del Clima; Argentina.es
dc.description.abstractPara poder asegurar calidad y confiabilidad en los datos de radiación solar de cualquier tipo, los sensores que la miden deben ser calibrados regularmente contra sensores patrones que posean trazabilidad con el Centro Mundial de Radiación (PMOD/WRC) de Davos. Una vez que han sido contrastados contra sensores patrones, las mediciones obtenidas por los sensores serán comparables a nivel local y global. En este trabajo se presenta los procedimientos y resultados de las dos intercomparaciones “outdoor” llevadas a cabo por el Servicio Meteorológico Nacional (SMN) durante el primer semestre del 2021 con la finalidad de calibrar los piranómetros marca Kipp&Zonen (K&Z) con número de serie 830285, 163812 y 120928. Ambas intercomparaciones fueron llevadas a cabo en el Observatorio Central de Buenos Aires (OCBA) del SMN. Luego de cada intercomparación se obtuvo el factor de calibración de los sensores participantes, así como la incerteza relativa asociada hallando diferencias de hasta 2.2% respecto de su última calibración.es
dc.description.abstractIn order to ensure quality and reliability in solar radiation data of any type, the sensors that measure it must be regularly calibrated against reference sensors that have traceability with the World Radiation Center (PMOD / WRC) in Davos. Once they have been contrasted against reference sensors, the measurements obtained by the sensors will be comparable locally and globally. This work presents the procedures and results of the two outdoor intercomparisons carried out by the National Meteorological Service (SMN) during the first semester of 2021 with the purpose of calibrate the Kipp & Zonen (K&Z) brand pyranometers with serial number 830285, 163812 and 120928. Both intercomparisons were carried out at the Central Observatory of Buenos Aires (OCBA) of the SMN. After each intercomparison, the calibration factor of the participating sensors was obtained, as well as the associated relative uncertainty, finding differences of up to 2.2% with respect to their last calibration.en
dc.formatapplication/pdf
dc.language.isospaes
dc.publisherServicio Meteorológico Nacional. Dirección Nacional de Ciencia e Innovación en Productos y Servicios. Dirección Central de Monitoreo del Clima.es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightshttps://creativecommons.org/licenses/by/2.5/ar/
dc.subjectCALIBRACIÓNes
dc.subjectPIRANÓMETROSes
dc.subjectTRAZABILIDADes
dc.titleCalibración de piranómetros s/n 163812, 830285 y 120928es
dc.typeInforme técnicoes